• Engine Starting Systems

    SuperTorque 8Z

    NiZn engine starting system

    SuperTorque 8R

    Integrated engine starting with rack/8Z/BBS/BSC/disconnects

    DC Power Systems

    PowerCab2

    24-300VDC, switchgear and industrial power system

    PowerCab

    24/48/120VDC, SCR

    MicroCab

    12/24/48VDC, switchmode

    Battery Chargers

    MicroGenius LE

    12/24VDC, 5-10A

    MicroGenius 2

    24/24VDC, 6-25A

    MicroGenius S2/S4

    12-120VDC, 6-100A

    EnerGenius DC

    120-240VDC, 6-800A, 3PH

    Battery Monitoring & Redundancy

    SC4 Battery Monitoring

    Comprehensive BMS for industrial and telecom applications

    Best Battery Selector

    BBS battery coupler

    BCS-120

    Control & alternator coupler

  • Applications

    Engine Starting

    Reliable DC power for engine starts

    Switchgear Power

    Backup power for critical switchgear

    Industrial DC Power

    Rugged power for industrial sites

    Battery Monitoring

    Battery monitoring systems and accessories

    Industries

    Data Centers

    Backup power infrastructure to maintain uptime

    Oil & Gas

    Power solutions for harsh environments

    Utilities

    Reliable power for grid operators

    Hospitals

    Backup power for life-critical systems

  • Support

    Technical Service & Support

    Get technical support

    Software Download Center

    Download firmware and software

    Software Revision History

    Updates to SENS software

    Warranties

    Product warranties and repairs

    Resources

    Technical Documents

    User manuals, CAD drawings, certifications, datasheets

    Insights

    Explore SENS power industry insights

    Case Studies

    Real world success stories

    White Papers

    Technical insights and innovations

    Genset Starting Education

    Prevent common genset starting failures

  • About

    About SENS

    Learn about our company

    Manufacturing

    U.S.-based manufacturing and scalable production

    Quality

    ISO 9001, worst-case design, codes & standards

    Partners

    Find a regional representative

    Company Updates

    News

    Company news and announcements

    Events

    Upcoming conferences and exhibitions

    Careers

    Working with SENS and open positions

Engine Starting Systems

SuperTorque 8Z

NiZn engine starting system

SuperTorque 8R

Integrated engine starting with rack/8Z/BBS/BSC/disconnects

DC Power Systems

PowerCab2

24-300VDC, switchgear and industrial power system

PowerCab

24/48/120VDC, SCR

MicroCab

12/24/48VDC, switchmode

Battery Chargers

MicroGenius LE

12/24VDC, 5-10A

MicroGenius 2

24/24VDC, 6-25A

MicroGenius S2/S4

12-120VDC, 6-100A

EnerGenius DC

120-240VDC, 6-800A, 3PH

Battery Monitoring & Redundancy

SC4 Battery Monitoring

Comprehensive BMS for industrial and telecom applications

Best Battery Selector

BBS battery coupler

BCS-120

Control & alternator coupler

Applications

Engine Starting

Reliable DC power for engine starts

Switchgear Power

Backup power for critical switchgear

Industrial DC Power

Rugged power for industrial sites

Battery Monitoring

Battery monitoring systems and accessories

Industries

Data Centers

Backup power infrastructure to maintain uptime

Oil & Gas

Power solutions for harsh environments

Utilities

Reliable power for grid operators

Hospitals

Backup power for life-critical systems

Featured Articles

NFPA110

Article

Healthcare Emergency Power: Reliability, Compliance & Risk

Switchmode_Article_Image

Article

What Switchmode Technology can do for Utilities

Support

Technical Service & Support

Get technical support

Software Download Center

Download firmware and software

Software Revision History

Updates to SENS software

Warranties

Product warranties and repairs

Resources

Technical Documents

User manuals, CAD drawings, certifications, datasheets

Insights

Explore SENS power industry insights

Case Studies

Real world success stories

White Papers

Technical insights and innovations

Genset Starting Education

Prevent common genset starting failures

Featured Content

Girtz_CaseStudy_WebsiteBanner

Case Study

How Girtz Industries Improved Their Engine Starting Tests

Mission_Critical_Power_2030_OnsiteGeneration

White Paper

What will the Mission for Critical Power Look like in 2030?

About

About SENS

Learn about our company

Manufacturing

U.S.-based manufacturing and scalable production

Quality

ISO 9001, worst-case design, codes & standards

Partners

Find a regional representative

Company Updates

News

Company news and announcements

Events

Upcoming conferences and exhibitions

Careers

Working with SENS and open positions

Latest News

Ribbon Cutting Cropped

NEWS

SENS Celebrates Colorado Expansion with Ribbon Cutting at New Longmont Manufacturing Facility

false

PBTRIM[x][y]

PBTRIM1[y]

PBTRIM2[y]

PBTRIM4[y]

PBTRIM5[y]

Have Questions or Need Help?

Our battery monitoring experts are here to help.

Remote Input Module (RIM)

View Datasheet

The Remote Input Module (RIM) is designed to operate in conjunction with our battery monitoring system. The RIM operates with site controllers via the “P-Bus” powered RS485 expansion bus. The site controller supplies operating power and communications signaling for the RIM slave over the P-Bus using common CAT5/RJ45interconnect cabling.

Expand through Daisy Chaining

Up to four RIMs can be operated in a “daisy-chain” configuration on each site controller P-Bus port. This provides a maximum expansion capability of eight RIMs per SC4 site controller. Each RIM provides six analog/digital interface points that can be used to monitor contact closures, logic states or to measure AC or DC analog voltages.

The status of each input for every RIM on the site controller’s P-Bus is viewable from the built-in web server, or via SNMP. RIM input states and voltages can be user-configured to generate alarms according to user-specified thresholds/states.

RIMs also contain an internal temperature sensor, an optional humidity sensor, and an interface to plug in a low-voltage wall transformer (Model PBT-WT-12) for measuring and monitoring commercial AC power-line voltage.

 

Monitor your equipment remotely

  • General-purpose monitoring of external equipment & facilities
  • Simple “point-of-use” modular architecture
  • Communications and powering provided via the “P-Bus” RS485 port on PBT host controller devices
  • Up to four RIMs on each host controller P-Bus port
  • Eight configurable & monitorable input points
  • Each input can be a binary (logic) state detection, a DC analog voltage measurement, or an RMS AC voltage measurement.
  • Internal temperature sensor
  • Optional internal humidity sensor
  • Supplied with wall-mount transformer for local utility AC power monitoring
  • Powered from P-Bus
  • Modular quick-disconnect terminal blocks

Datasheet

  • Specifications
  • Site Control Web Interface
Number Of User Defined Inputs 6
Input Types Analog, contact closure, or logic level; user definable
Analog Range -12 V to +12 V
DC Analog Measurement Resolution +/- 25 mV
DC Analog Measurement Accuracy +/- 2%
Logic Level Thresholds User definable within analog range
AC Analog Measurement User definable per input; RMS measurement
Optional Commercial Line Voltage Measurement (In Addition To 6 User I/O Inputs) 50 VAC to 150 VAC RMS nom; +/- 5%
Internal Temperature Sensor -40 °C to +60 °C; +/-2%
Optional Humidity Sensor 5% RH to 95% RH; +/- 2%
Size 2.6” x 2.6” x 1” nominal
Interface To Controller P-Bus RS485 on RJ45 connector; power supplied by daisy chain
Environment -40 °C to +60 °C; 0-95% RH

 

Power
Model
Features
PBT-RIM-1[y] 6 standard inputs
PBT-RIM-2[y] 4 standard inputs;
2 temperature inputs
PBT-RIM-4[y] 6 temperature inputs
PBT-RIM-5[y] For discharge/charge current sensor model PBT-PA-DCC-1000/100

 

y = “H” signifies internal humidity sensor

Mounting bracket included.

A full line of measuring and monitoring accessories is available. Contact us for more information.

 

have questions or need help?

The SENS team is here to help. If you have questions or need help, reach out and start a conversation.