P13000PS120S0360A012030000
P32501F312031500B04S830010
P13000PS024S075LA011510000
P13001F312031000A02S810010
P13000FS120S050BA011010000
P33001FS1201050LA01S810010
P53003FS120S0250A011010003
P53003FS120S0250A011010002
P33001F312031000A02S810010
P64203CV12031000AB3S820012
P62303CV12031000AB3S820012
P33001FH12031000B02S810010
P13000FS120S025BA011010000
P12501FH12031000BA4S810010
P13000FS120S0750A012010000
P33001F312031000B02S810012
P13000PS024S1500A031530002
P53003C312030250BA2S810011
P33001F312030500B02S810012
P13000PS120S0540A01H210000
P33001FH12031000A02S810010
P62303CV12031000A03S820012
P64203CV12031000A03S820012
P13001FH12031000B03S830010
P13000FS120S0250A011010000
P33001PS120S018BB011010000
P13000F1120S0500BA11010001
P12601CS120S1000A032040000
P33001F312030500B02S810010
P13000FS120S0500A011010000
P33001F2120H1000A02S810010
P32501F112010750A05S810010
P4200100120S00000X8S000012
PowerCab™2
The PowerCab2 is a fully integrated, factory-assembled DC power platform designed to provide non-stop, reliable power for mission-critical industrial applications.
Request a custom technical quote today.
Configurable Factory-Packaged DC UPS
DC power is essential for switchgear, protection systems, controls, and backup operations. The PowerCab2 is designed, assembled, and tested as a complete system to reduce reliability risk in mission-critical applications.
Delivered fully configured and ready for installation, the PowerCab2 simplifies DC power system deployment while reducing engineering effort, installation time, cost, and project risk. It supports indoor and outdoor applications and is available in configurations from 24-240+ VDC.
Available options include expansion cabinets, load centers, electrical distribution, low-voltage disconnects, battery monitoring, inverters, and transfer switches. UL Listed for installations throughout the United States and Canada.
| DC Voltage Range | 24–240+ VDC (configurable) |
| Power Conversion | Compact, efficient, hardened switchmode power conversion for industrial energy storage applications |
| Ingress protection | NEMA 1 (indoor) or NEMA 3R (outdoor) |
| Battery Type | Salt (SMC), VRLA or Lithium Titanate Oxide (LTO) |
| DC Breakers | Up to 32 two-pole breakers in a single 15” cabinet |
| Certifications | UL Listed (US & Canada) |
| Assembly | Factory-built in ISO 9001-2015 facility |
Built for Mission-Critical Reliability
100+ components in one system
Instead of coordinating multiple vendors, lead times, and purchase orders for individual components, you receive a single, factory-assembled, UL-listed solution that arrives prepared for seamless, drop-in installation.
Up to 87% floor space savings
The PowerCab2 delivers 400 amps in the footprint of a typical 30-amp charger and consumes up to 87% less floor space than traditional configurations.
Reduce installation complexity
Arrives ready to install, eliminating guesswork, missing parts, and extra labor. The result is a faster installation, lower overall costs, and a more predictable in-service date.
Inside the PowerCab2
Documents
Product Photos
3-Phase, NEMA 3R-rated hyperscale configuration featuring 3 SMC (salt) batteries, and additional AC controls and distribution
Frequently Asked Questions
-
Standard: energy storage/batteries, power conversion/chargers, electrical distribution and load centers, HMI interface, AC/DC breakers
-
Optional: battery monitoring, high interrupt breakers, shunt-trip breakers, bus bars/bulk termination, wire marking (PIP compliance), redundancy, inverters, and transfer switches.
-
Yes, the PowerCab2 can be ordered with a single part number, while incorporating the application specifics and customizing the battery choice and cabinet configurations.
-
A piecemeal DC system requires installers to assemble racks, mount and wire battery cells, size protective devices, run conduit, and integrate chargers and panels—often with parts from multiple sources. In contrast, the UL-Listed SENS PowerCab2 is fully engineered, factory-assembled in an ISO9001-2015 facility, and fully tested before shipment. It arrives ready to install, eliminating guesswork, missing parts, and extra labor. This shortens installation time, lowers cost, and provides a predictable in-service date.
Yes, the PowerCab2 is available in NEMA 1 for indoor applications and NEMA 3R for outdoor applications. Salt batteries or high temperature VRLA batteries are recommended for outdoor applications.
-
It is specifically engineered for hardened industrial applications like utility, oil and gas, and other mission critical applications.
-
Every component is factory assembled, tested, and arrives on-site ready to be wired, commissioned and quickly put into service.
-
Our state-of-the-art silicon-carbide switchmode power conversion technology offers the most robust rectification in the smallest footprint matching the demand for any customer.
-
The biggest safety risk in DC systems is lifting and handling batteries. In the PowerCab2, batteries are factory-installed, wired, and secured, eliminating hazardous on-site lifting. The entire cabinet can be positioned with a forklift, pallet jack, or crane.
-
PowerCab2 uses dead-front panels to keep all internal components touch-safe when the doors are open, preventing accidental contact with live terminals. Most “build-your-own” systems offer only minimal or no protective covers.
-
The charger, battery, distribution panel, and cabinet are all UL-listed—something many assembled-on-site systems lack.
Yes, the PowerCab2 is UL/C-UL listed for installations across the US and Canada.
The PowerCab2 is designed to all North American and IEEE seismic requirements including OSHPD. Testing to be completed in Q2 2026.
A piecemeal DC system requires installers to assemble racks, mount and wire battery cells, size protective devices, run conduit, and integrate chargers and panels—often with parts from multiple sources. In contrast, the UL-Listed SENS PowerCab2 is fully engineered, factory-assembled in an ISO9001-2015 facility, and fully tested before shipment. It arrives ready to install, eliminating guesswork, missing parts, and extra labor. This shortens installation time, lowers cost, and provides a predictable in-service date.
Component cost is only a small part of total project expense. Engineering, purchasing, installation, on-site testing, approvals, and after-sale support add significantly. Many users also report smoother AHJ approvals with a UL-Listed, factory-built cabinet versus an on-site, a-la-carte system. Because it reduces engineering and installation labor, PowerCab2 often delivers the lowest total cost compared to “build-your-own” DC systems.
PowerCab2’s battery and DC load breakers are 2-pole UL 489 listed at 14,000 AIC (amps interrupting current) at 125 volts DC. This is substantially higher than any other compact circuit breaker on the market.
-
Standard: your choice of Sodium Metal Chloride (Salt Batteries), front terminal VRLA, high temperature TPPL VRLA, AGM.
-
SENS can integrate other chemistries as specified, including Lithium Titanate Oxide (LTO).
-
SMC batteries are ideal for low-rate loads (3–12 hours), extreme temperatures, high safety requirements, and long, maintenance-free life.
-
Sodium-Metal-Chloride chemistry delivers long life even in high heat, a compact footprint, and built-in intelligence through per-module battery management.
-
Salt batteries require no HVAC and outperform many technologies in both hot and cold environments, operating continuously from –20°C to +60°C with IP55 protection.
-
VRLA is an industry standard economical battery with performance that matches many indoor switchgear application load profiles.
-
The PowerCab2 can be configured with parallel VRLA battery strings for N+1 brute force reliability.
-
Front terminal batteries enable easy operation, maintenance and fast change-out if needed.
Choose LTO if you need an extremely high-rate capable battery in the smallest footprint, wide temperature range, and long calendar life.
No clearance is required in back or on the sides. PowerCab2 employs thermostatically controlled forced-air cooling, entering through the front door and exiting the top rear of the cabinet. Because of this, the sides can be mounted essentially flush with walls or other equipment. It is recommended to leave a few inches beyond the exhaust hood of the cabinet.